Skip to main content

Loop heat pipes (LHPs) are used in multiple terrestrial and space applications. Transient analysis of conventional and advanced loop heat pipes with complex radiators under varying conditions where the heat load and the effective sink temperature change in time can be best accomplished using Thermal Desktop™.

SINDA/FLUINT (Ref 1-7) is the NASA-standard heat transfer and fluid flow analyzer for thermal control systems. Because of its general formulation, it is also used in other aerospace specialties such as environmental control (ECLSS) and liquid propulsion, and in terrestrial industries such as electronics packaging, refrigeration, power generation, and transportation industries.

This paper describes revolutionary advances in SINDA/FLUINT, the NASA-standard heat transfer and fluid flow analyzer, changing it from a traditional point-design simulator into a tool that can help shape preliminary designs, rapidly perform parametrics and sensitivity studies, and even correlate modeling uncertainties using available test data.

Over the past 15 years, the industry standard tool for thermal analysis, SINDA, has been expanded to include advanced thermodynamic and hydrodynamic solutions (“FLUINT”). With the recent culmination of the unique modeling tools that are described in this paper, and with concurrent expansions described elsewhere (Ref 1), SINDA/ FLUINT has arguably become the most complete generalpurpose thermohydraulic network analyzer that is available.

Recent years have witnessed more improvement to the SINDA/FLUINT thermohydraulic analyzer than at any other time in its long history. These improvements have included not only expansions in analytic power, but also the additions of high-level modules that offer revolutions in thermal/ fluid engineering itself.

Over the past 15 years, the industry standard tool for thermal analysis, SINDA, has been expanded to include advanced thermodynamic and hydrodynamic solutions (“FLUINT”). With the recent culmination of the unique modeling tools, SINDA/ FLUINT has arguably become the most complete general-purpose thermohydraulic network analyzer that is available.

In recent years, loop heat pipe (LHP) technology has transitioned from a developmental technology to one that is flight ready. The LHP is considered to be more robust than capillary pumped loops (CPL) because the LHP does not require any preconditioning of the system prior to application of the heat load, nor does its performance become unstable in the presence of two-phase fluid in the core of the evaporator. However, both devices have a lower limit on input power: below a certain power, the system may not start properly.

The NASA-standard thermohydraulic analyzer, SINDA/ FLUINT, has been used to model various aspects of loop heat pipe  (LHP) operation for more than 12 years. Indeed, this code has many features that were specifically designed for just such specialized tasks, and is unique in this respect.

The NASA standard tool for thermohydraulic analysis, SINDA/FLUINT, includes thermodynamic and hydrodynamic solutions specifically targeted at the growing demand for design and analysis of liquid propulsion systems. Applications in this field have included:

e-Thermal is a vehicle level thermal analysis tool developed by General Motors to simulate the transient performance of the entire vehicle HVAC and Powertrain cooling system. It is currently in widespread (global) use across GM. This paper discusses the details of the airconditioning module of e-Thermal. Most of the literature available on transient modeling of the air conditioning systems is based on finite difference approach that require large simulation times. This has been overcome by appropriately modeling the components using Sinda/Fluint.