SINDA/FLUINT (Ref 1-7) is the NASA-standard heat transfer and fluid flow analyzer for thermal control systems. Because of its general formulation, it is also used in other aerospace specialties such as environmental control (ECLSS) and liquid propulsion, and in terrestrial industries such as electronics packaging, refrigeration, power generation, and transportation industries.

This paper describes revolutionary advances in SINDA/FLUINT, the NASA-standard heat transfer and fluid flow analyzer, changing it from a traditional point-design simulator into a tool that can help shape preliminary designs, rapidly perform parametrics and sensitivity studies, and even correlate modeling uncertainties using available test data.

The NASA-standard thermohydraulic analyzer, SINDA/ FLUINT, has been used to model various aspects of loop heat pipe  (LHP) operation for more than 12 years. Indeed, this code has many features that were specifically designed for just such specialized tasks, and is unique in this respect.

The NASA standard tool for thermohydraulic analysis, SINDA/FLUINT, includes thermodynamic and hydrodynamic solutions specifically targeted at the growing demand for design and analysis of liquid propulsion systems. Applications in this field have included:

This paper describes the application of the general purpose SINDA/FLUINT thermohydraulic analyzer to the modeling of vapor compression (VC) cycles such as those commonly used in automotive climate control and building HVAC systems. The software is able to simulate transient operation of vapor compression cycles, predicting pressures, coefficients of performance, and condenser/evaporator liquid positions in a closed two-phase system with a fixed fluid charge.

This paper describes the need for dynamic (transient) simulation of automotive air conditioning systems, the reasons why such simulations are challenging, and the applicability of a general purpose off-the-shelf thermohydraulic analyzer to answer such challenges.

An overview of modeling methods for the basic components are presented, along with relevant approximations and their effect on speed and accuracy of the results.

Modeling lessons learned form Ford, Visteon, GM, Delpi, Danfoss, etc.

The pressure of the cryogen within a Dewar determines the operating temperature since the cryogen is typically in a saturated state. Thus, the operating temperature of a Dewar is directly related to the ambient pressure external to the Dewar and the flow losses associated with venting cryogen. Given the low vapor pressures of some cryogens, such as solid hydrogen, the vent flow from Dewars used in space can enter the transitional and molecular flow regimes.